Viz Mosart Administrator Guide

Version 3.9 | Published November 04, 2019 ©

AV Automation Devices - Audio

Viz Mosart is capable of connecting a variety of Audio Mixers available from several different manufacturers.

Select the correct Audio Mixer from the menu for your broadcast environment. AV Automation handles the following:

See Also

Audio Mixer

images/download/attachments/57242802/configuration_avauto-audiomix-setup-window.png

  • Use Audio mixer: Check the box to enable the audio mixer functionality.

  • Audio mixer type:

    • Calrec: Calrec Serial Protocol

    • DHD: RM4200-D Fa. DHD

    • LAWO RMNOPL: RemoteMNOPL protocol

    • LAWO ZIRKON: RAS subset protocol

    • SSL: Light Broadcast Automation protocol

    • STAGETEC: Stagetec RAS protocol

    • STUDER_3000: For audio mixers supporting the MONITORA protocol

    • WHEATSTONE: Wheatstone Mixer Automation Protocol

    • YAMAHA_O2: For audio mixers controlled through MIDI control change and parameter change

    • STUDER VISTA: Control of the Studer Vista series via the Ember protocol

  • Serial (Calrec, Lawo, Studer, etc.): Serial port connected to the audio mixer (when Serial radio button is selected).

  • TCP/IP: Hostname (or IP address) and port to communicate with the audio mixer (when TCP/IP radio button is selected).

  • Backup hostname and port (Lawo): Hostname (or IP address) and port to the backup audio mixer console.

  • Set user labels on console: When selected, user labels on the Lawo console are overwritten.

  • MidiCh (Yamaha): MIDI channel assigned to the audio mixer.

  • Midi Output port (Yamaha): System MIDI port to communicate with the audio mixer.

  • Default fade time: Time in frames for fading open faders with the manual fade function (CTRL+F).

  • Default snapshot: Snapshot to recall when starting the automation (MIDI parameter change).

  • Audio effect server: Name for the Audio effect fader. This fader will open if effect transitions are used.

  • Send reset command on connect: Used for STUDER3000 SW 2.2, or lower. Recalls a default setup for the Mixer panel.

  • Visible audio faders: Maximum visible faders in AV Automation.

  • Use sound player: Check box to enable connection to the Audio Player.

  • Host: Hostname or IP address to the computer running the Audio Player.

  • Default directory: Directory for the audio files (on the Audio Player’s PC).

AV Automation Audio Mixer Compatibility Table

CAL REC

DHD

LAWO RMNOPL

LAWO ZIR KON

SSL

STAG ETEC

STUDER 3000

WheatStone

YAMAHA O2

STUDER VISTA

EUPHONIX

Serial

x

x

x

TCP/IP

x

x

x

MidiCh

x

Midiport

x

Hostname

x

x

x

x

x

x

x

x

x

Port

x

x

x

x

x

x

x

x

x

x

Backuphost name

x

BackupPort

x

Faderinputoffset

x

Useemberprotocol

x

Comportaudiomixer

x

x

x

x

x

x

Loudness Control

images/download/attachments/57242802/configuration_avauto-loudness.png

  • Use loudness controller: Check the box to enable loudness control.

  • Loudness controller type: JUNGER T*AP

  • Triggers/levels: Name of triggers or loudness levels, one for each line. These will appear in a tool-tip menu in the Template editor, and must correspond to the configuration in the loudness controller(s).

  • Channels: Fixed values. For Junger T*AP there are 4 stereo channels per host. Connections to the audio faders are configured in A/V Setup/Edit/Audio config/Loudness channel.

  • Host:port: Hostname or IP address and optional port number for each controller.