Viz Mosart Administrator Guide

Version 5.6 | Published March 27, 2024 ©

Audio

Viz Mosart connects to a variety of audio devices, from various manufacturers.

Select the required audio device from AV Automation > Devices > Preferences > Audio.

Audio Mixer

This tab enables setting-up of the main mixer and optionally, a backup.

images/download/attachments/140812215/audioMixer.png

  • Use Audio mixer: Enables the audio mixer functionality.

Audio Mixer Types

Audio mixer

Protocol

Supported hardware / Comments

Interface

Ardour / Harrison Mixbus VBM

OSC

Harrison Mixbus VBM

  • Ensure OSC is enabled in the Control Surface Protocol selector and that in the OSC Setup tab, Viz Mosart Audio mixer properties match:

    images/download/attachments/140812215/mixBus.png


    In the example above, where the port number (here 3819) match correctly.

  • The input field Port Mode must be: Manual - Specify Below.

  • The input field Reply Manual Port can be any value, including empty.

  • The Mixer name must match the input name, Physical Input is blank:

    images/download/attachments/140812215/OSC.png

Note: Harrison MixBus 32C is not supported.

UDP

CALREC

RAP


RS-422, TCP/IP (Artemis)

DHD

DHD RM4200-D v2.02


TCP/IP

EUPHONIX

RAP


COM

LAWO RMNOPL

RemoteMNOPL

Lawo mc²

TCP/IP

LAWO ZIRKON

RAS, Lawo Zirkon subset


RS-422 or TCP/IP

LAWO EMBER+

Ember+

Lawo audio mixers with A__UHD Core. This requires that the Lawo audio mixer has correct firmware and settings to allow Ember+ control (contact Lawo for details about which specific audio mixer models support this functionality).

TCP/IP

MIDIMIXER

Sanford.Multimedia


MIDI

SSL

Light Broadcast Automation protocol, SSL Broadcast Automation Control Specification – v1.0


RS-422 or TCP/IP

STAGETEC

Stagetec Diamond RAS protocol, Monitora RAS


COM

STUDER_3000

Monitora + Ember, Ember 1.0

Studer OnAir 3000

RS-232 or TCP/IP

STUDER_VISTA

Ember

Studer Vista

TCP/IP

VIZENGINE

n/a

Viz Opus only

TCP/IP

WHEATSTONE

Wheatstone Mixer Automation Protocol v.1.4


TCP/IP

YAMAHA_O2

MIDI

Yamaha 01V96, DM1000, DM2000, DME64N, O2V96, LS9, CL5

MIDI

vizrt-ips

NewTek

Vizrt Group/NewTek IPseries mixers. TriCaster, VMC, Viz Verdi, Viz Vectar

TCP/IP

  • Serial (Calrec, Lawo, Studer, etc.): Serial port connected to the audio mixer, when Serial radio button is selected.

  • TCP/IP: Hostname or IP address and port to communicate with the audio mixer, when TCP/IP radio button is selected. Note that for Calrec it is possible to configure a main and backup audio mixer by specifying two comma separated hostname values and port values.

  • Hostname: Hostname or IP address of the audio mixer.

  • Port: Port on the audio mixer.

  • Local port: (Ardour only) The mixer will send messages to this port on the Mosart server. Use 8000 unless there is a good reason for choosing another port.

  • Backup hostname and port (LAWO RMNOPL): Hostname (or IP address) and port to the backup audio mixer console.

  • Set user labels on console: When selected, user labels on the (non-EMBER+) Lawo or Vista console are overwritten.

  • MidiCh (MIDIMIXER and YAMAHA_O2): MIDI channel assigned to the audio mixer. Depending on mixer model, this setting may have to correspond to settings on the mixer.

  • Midi Input port (MIDIMIXER and YAMAHA_O2): System MIDI input port to communicate with the audio mixer.

  • Midi Output port (MIDIMIXER and YAMAHA_O2): System MIDI output port to communicate with the audio mixer.

  • Default fade time: Time in frames for fading open faders with the manual fade function (CTRL+F).

  • Default snapshot: Snapshot to recall when starting the automation (MIDI parameter change).

  • Audio effect server: Name for the Audio effect fader. This fader will open if effect transitions are used.

  • Send reset command on connect: Used for STUDER3000 SW 2.2, or lower. Recalls a default setup for the Mixer panel.

  • Visible audio faders: Maximum visible faders in AV Automation.

AV Automation Audio Mixer Availability Table


Serial

TCP/IP

MidiCh

Midiport

Hostname

Port

Backup
host name

Backup
Port

Faderinput
offset

Useember
protocol

Comport
audiomixer

Ardour





X

X






CALREC

x

x



x

x





x

DHD


x



x

x






EUPHONIX

x










x

LAWO
RMNOPL


x



x

x

x

x




LAWO
ZIRKON

x

x



x

x





x

LAWO EMBER+





x

x






MIDI
MIXER



x

x








SSL

x








x


x

STAGETEC

x

x



x

x





x

STUDER
3000

x

x



x

x




x

x

STUDER
VISTA


x



x

x






VIZ
ENGINE


x



x

x






WHEAT
STONE


x



x

x






YAMAHA
O2



x

x








Vizrt
ips


x



x

x






Audio Player

A basic audio player is always included as standard in a Viz Mosart.

images/download/thumbnails/140812215/ap_player.png

Requirements

Refer to general section Prerequisites (section Viz Mosart Audio Player).

Setting Up an Audio Player

Refer to section Audio Players.

Operating an Audio Player

Refer to section Playing Audio in the Viz Mosart User Guide.

Loudness Control

A loudness control from Junger.

images/download/attachments/140812215/conf_ava-vol.png

  • Use loudness controller: Check the box to enable loudness control.

  • Loudness controller type: JUNGER T*AP.

  • Triggers/levels: Name of triggers or loudness levels, one for each line. These will appear in a tool-tip menu in the Template editor, and must correspond to the configuration in the loudness controller(s).

  • Channels: Fixed values. For Junger T*AP there are four stereo channels per host. Connections to the audio faders are configured in A/V Setup/Edit/Audio config/Loudness channel.

  • Host:port: Hostname or IP address and optional port number for each controller.

Note: If the root node name is different than T*AP the name must be set in the AVA configuration property JungerRoot .

See Also